Review





Similar Products

90
Cytiva Europe leukocyte separation filter
Schematic representation of hiPSC generation using a prototype semi-automated device (A) Leukocyte <t>separation</t> device. This device performs: 1) Fill the flow path with PBS and purge the air. 2) Draw blood from the blood bag into syringe pump #1. 3) Deliver blood from syringe pump #1 and capture white blood cells using cell filter. 4) Rinse away excess red blood cells captured by cell filter with PBS. 5) Flush PBS through syringe pump #2 and collect the white blood cells from cell filter into syringe #3. 6) Deliver the contents of syringe #3 into the spiral flow path to collect leukocytes. (B) Leukocyte culture device. This device performs: 1) Fill the flow path with PBS and purge the air. 2) Draw blood from the blood bag into syringe pump #1. 3) Deliver blood from syringe pump #1 and capture white blood cells using cell filter. 4) Rinse away excess red blood cells captured by cell filter with PBS. 5) Flush PBS through syringe pump #2 and collect the white blood cells from cell filter into syringe #3. 6) Deliver the contents of syringe #3 into the spiral flow path to collect leukocytes. (C) SeV transduction device. This device performs: 1) Recover leukocytes from the previous step using syringe pump #7. 2) Pass the cells from syringe pump #7 through filter #3 and into syringe pump #8 to remove aggregated cells. 3) Transfer the cells from syringe pump #8 to the incubator #2, and mix the leukocytes with SeV vectors. 4) Infect SeV vectors within the incubator #2 to generate hiPSCs. 5) Recover using syringe #11, and transfer these hiPSCs to syringe #13.
Leukocyte Separation Filter, supplied by Cytiva Europe, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/white+blood+cell+(wbc)/Acrodisc+WBC+(white+Blood+cell)+syringe+filter/pmc13788381-211-7-11
Average 90 stars, based on 1 article reviews
leukocyte separation filter - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

86
Sysmex Corporation white blood cell count wbc
Schematic representation of hiPSC generation using a prototype semi-automated device (A) Leukocyte <t>separation</t> device. This device performs: 1) Fill the flow path with PBS and purge the air. 2) Draw blood from the blood bag into syringe pump #1. 3) Deliver blood from syringe pump #1 and capture white blood cells using cell filter. 4) Rinse away excess red blood cells captured by cell filter with PBS. 5) Flush PBS through syringe pump #2 and collect the white blood cells from cell filter into syringe #3. 6) Deliver the contents of syringe #3 into the spiral flow path to collect leukocytes. (B) Leukocyte culture device. This device performs: 1) Fill the flow path with PBS and purge the air. 2) Draw blood from the blood bag into syringe pump #1. 3) Deliver blood from syringe pump #1 and capture white blood cells using cell filter. 4) Rinse away excess red blood cells captured by cell filter with PBS. 5) Flush PBS through syringe pump #2 and collect the white blood cells from cell filter into syringe #3. 6) Deliver the contents of syringe #3 into the spiral flow path to collect leukocytes. (C) SeV transduction device. This device performs: 1) Recover leukocytes from the previous step using syringe pump #7. 2) Pass the cells from syringe pump #7 through filter #3 and into syringe pump #8 to remove aggregated cells. 3) Transfer the cells from syringe pump #8 to the incubator #2, and mix the leukocytes with SeV vectors. 4) Infect SeV vectors within the incubator #2 to generate hiPSCs. 5) Recover using syringe #11, and transfer these hiPSCs to syringe #13.
White Blood Cell Count Wbc, supplied by Sysmex Corporation, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/white+blood+cell+(wbc)/blood+counts/pm42312388-15683-16-61
Average 86 stars, based on 1 article reviews
white blood cell count wbc - by Bioz Stars, 2026-11
86/100 stars
  Buy from Supplier

86
Biocell Technology splice variants white blood cells wbcs
Schematic representation of hiPSC generation using a prototype semi-automated device (A) Leukocyte <t>separation</t> device. This device performs: 1) Fill the flow path with PBS and purge the air. 2) Draw blood from the blood bag into syringe pump #1. 3) Deliver blood from syringe pump #1 and capture white blood cells using cell filter. 4) Rinse away excess red blood cells captured by cell filter with PBS. 5) Flush PBS through syringe pump #2 and collect the white blood cells from cell filter into syringe #3. 6) Deliver the contents of syringe #3 into the spiral flow path to collect leukocytes. (B) Leukocyte culture device. This device performs: 1) Fill the flow path with PBS and purge the air. 2) Draw blood from the blood bag into syringe pump #1. 3) Deliver blood from syringe pump #1 and capture white blood cells using cell filter. 4) Rinse away excess red blood cells captured by cell filter with PBS. 5) Flush PBS through syringe pump #2 and collect the white blood cells from cell filter into syringe #3. 6) Deliver the contents of syringe #3 into the spiral flow path to collect leukocytes. (C) SeV transduction device. This device performs: 1) Recover leukocytes from the previous step using syringe pump #7. 2) Pass the cells from syringe pump #7 through filter #3 and into syringe pump #8 to remove aggregated cells. 3) Transfer the cells from syringe pump #8 to the incubator #2, and mix the leukocytes with SeV vectors. 4) Infect SeV vectors within the incubator #2 to generate hiPSCs. 5) Recover using syringe #11, and transfer these hiPSCs to syringe #13.
Splice Variants White Blood Cells Wbcs, supplied by Biocell Technology, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/white+blood+cell+(wbc)/blood+cells+splice+variants+wbcs+white/med_rxiv__64898__2026__04__15__26349265-38-3-18
Average 86 stars, based on 1 article reviews
splice variants white blood cells wbcs - by Bioz Stars, 2026-11
86/100 stars
  Buy from Supplier

86
Sysmex Corporation white blood cell wbc count
Schematic representation of hiPSC generation using a prototype semi-automated device (A) Leukocyte <t>separation</t> device. This device performs: 1) Fill the flow path with PBS and purge the air. 2) Draw blood from the blood bag into syringe pump #1. 3) Deliver blood from syringe pump #1 and capture white blood cells using cell filter. 4) Rinse away excess red blood cells captured by cell filter with PBS. 5) Flush PBS through syringe pump #2 and collect the white blood cells from cell filter into syringe #3. 6) Deliver the contents of syringe #3 into the spiral flow path to collect leukocytes. (B) Leukocyte culture device. This device performs: 1) Fill the flow path with PBS and purge the air. 2) Draw blood from the blood bag into syringe pump #1. 3) Deliver blood from syringe pump #1 and capture white blood cells using cell filter. 4) Rinse away excess red blood cells captured by cell filter with PBS. 5) Flush PBS through syringe pump #2 and collect the white blood cells from cell filter into syringe #3. 6) Deliver the contents of syringe #3 into the spiral flow path to collect leukocytes. (C) SeV transduction device. This device performs: 1) Recover leukocytes from the previous step using syringe pump #7. 2) Pass the cells from syringe pump #7 through filter #3 and into syringe pump #8 to remove aggregated cells. 3) Transfer the cells from syringe pump #8 to the incubator #2, and mix the leukocytes with SeV vectors. 4) Infect SeV vectors within the incubator #2 to generate hiPSCs. 5) Recover using syringe #11, and transfer these hiPSCs to syringe #13.
White Blood Cell Wbc Count, supplied by Sysmex Corporation, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/white+blood+cell+(wbc)/blood+counts/pm41923554-30-18-26
Average 86 stars, based on 1 article reviews
white blood cell wbc count - by Bioz Stars, 2026-11
86/100 stars
  Buy from Supplier

86
Charles River Laboratories white blood cell count wbc female new zealand white nzw rabbits
Schematic representation of hiPSC generation using a prototype semi-automated device (A) Leukocyte <t>separation</t> device. This device performs: 1) Fill the flow path with PBS and purge the air. 2) Draw blood from the blood bag into syringe pump #1. 3) Deliver blood from syringe pump #1 and capture white blood cells using cell filter. 4) Rinse away excess red blood cells captured by cell filter with PBS. 5) Flush PBS through syringe pump #2 and collect the white blood cells from cell filter into syringe #3. 6) Deliver the contents of syringe #3 into the spiral flow path to collect leukocytes. (B) Leukocyte culture device. This device performs: 1) Fill the flow path with PBS and purge the air. 2) Draw blood from the blood bag into syringe pump #1. 3) Deliver blood from syringe pump #1 and capture white blood cells using cell filter. 4) Rinse away excess red blood cells captured by cell filter with PBS. 5) Flush PBS through syringe pump #2 and collect the white blood cells from cell filter into syringe #3. 6) Deliver the contents of syringe #3 into the spiral flow path to collect leukocytes. (C) SeV transduction device. This device performs: 1) Recover leukocytes from the previous step using syringe pump #7. 2) Pass the cells from syringe pump #7 through filter #3 and into syringe pump #8 to remove aggregated cells. 3) Transfer the cells from syringe pump #8 to the incubator #2, and mix the leukocytes with SeV vectors. 4) Infect SeV vectors within the incubator #2 to generate hiPSCs. 5) Recover using syringe #11, and transfer these hiPSCs to syringe #13.
White Blood Cell Count Wbc Female New Zealand White Nzw Rabbits, supplied by Charles River Laboratories, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/white+blood+cell+(wbc)/rabbits+white+zealand/pm41779697-52-15-26
Average 86 stars, based on 1 article reviews
white blood cell count wbc female new zealand white nzw rabbits - by Bioz Stars, 2026-11
86/100 stars
  Buy from Supplier

86
Kaggle Inc wbc images 41 pre trained cnn white blood cell 99 70
Schematic representation of hiPSC generation using a prototype semi-automated device (A) Leukocyte <t>separation</t> device. This device performs: 1) Fill the flow path with PBS and purge the air. 2) Draw blood from the blood bag into syringe pump #1. 3) Deliver blood from syringe pump #1 and capture white blood cells using cell filter. 4) Rinse away excess red blood cells captured by cell filter with PBS. 5) Flush PBS through syringe pump #2 and collect the white blood cells from cell filter into syringe #3. 6) Deliver the contents of syringe #3 into the spiral flow path to collect leukocytes. (B) Leukocyte culture device. This device performs: 1) Fill the flow path with PBS and purge the air. 2) Draw blood from the blood bag into syringe pump #1. 3) Deliver blood from syringe pump #1 and capture white blood cells using cell filter. 4) Rinse away excess red blood cells captured by cell filter with PBS. 5) Flush PBS through syringe pump #2 and collect the white blood cells from cell filter into syringe #3. 6) Deliver the contents of syringe #3 into the spiral flow path to collect leukocytes. (C) SeV transduction device. This device performs: 1) Recover leukocytes from the previous step using syringe pump #7. 2) Pass the cells from syringe pump #7 through filter #3 and into syringe pump #8 to remove aggregated cells. 3) Transfer the cells from syringe pump #8 to the incubator #2, and mix the leukocytes with SeV vectors. 4) Infect SeV vectors within the incubator #2 to generate hiPSCs. 5) Recover using syringe #11, and transfer these hiPSCs to syringe #13.
Wbc Images 41 Pre Trained Cnn White Blood Cell 99 70, supplied by Kaggle Inc, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/white+blood+cell+(wbc)/models+pre+trained/pm41430086-258-24-42
Average 86 stars, based on 1 article reviews
wbc images 41 pre trained cnn white blood cell 99 70 - by Bioz Stars, 2026-11
86/100 stars
  Buy from Supplier

96
Proteintech white blood cell wbc
Test of antithrombosis properties of SSCMC in vitro and in vivo . a) Surgical schematic of in vitro blood circulation in rabbits. b) Diagrams of blood cells adhering to the inner lumen of both catheters before and after modification of in vitro blood circulation for 2 h. c) Comparison of blood cells adhering to the surfaces of both catheters before and after modification of the inner lumen of both catheters under SEM. d) ∼ f) Quantification of thrombus weight, lumen occlusion and blood flow rate formed in the lumen of the two catheters, respectively. g) Blood circulation modeling to perform blood correlation analysis. h) Thrombin-antithrombin III enzyme complex (TAT) (an early marker of coagulation activation). i) Tissue-type fibrinogen activator-inhibitor 1 complex (PIC) (risk indicator for venous thromboembolism). j) Thrombomodulin (TM). k) Platelets (PLT). l) <t>White</t> <t>blood</t> <t>cells</t> <t>(WBC).</t> m) Serum albumin (ALB). n) Acute inflammation indicator c-reactive protein (CRP). o) Tumor necrosis factor (TNF-α). p) IL-6. q) IL-10. r) Liver function indicator alanine aminotransferase (ALT). s) Kidney function indicator serum creatinine (Scr). Error bar represents the mean ± SD. Significance was calculated by one-way analysis of variance. ∗∗∗∗ p < 0.0001. N = 4, averaged.
White Blood Cell Wbc, supplied by Proteintech, used in various techniques. Bioz Stars score: 96/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/white+blood+cell+(wbc)/CEL+Antibody/pmc12593591-211-36-43
Average 96 stars, based on 1 article reviews
white blood cell wbc - by Bioz Stars, 2026-11
96/100 stars
  Buy from Supplier

86
Takeda agriculture wbc white blood cell count
Test of antithrombosis properties of SSCMC in vitro and in vivo . a) Surgical schematic of in vitro blood circulation in rabbits. b) Diagrams of blood cells adhering to the inner lumen of both catheters before and after modification of in vitro blood circulation for 2 h. c) Comparison of blood cells adhering to the surfaces of both catheters before and after modification of the inner lumen of both catheters under SEM. d) ∼ f) Quantification of thrombus weight, lumen occlusion and blood flow rate formed in the lumen of the two catheters, respectively. g) Blood circulation modeling to perform blood correlation analysis. h) Thrombin-antithrombin III enzyme complex (TAT) (an early marker of coagulation activation). i) Tissue-type fibrinogen activator-inhibitor 1 complex (PIC) (risk indicator for venous thromboembolism). j) Thrombomodulin (TM). k) Platelets (PLT). l) <t>White</t> <t>blood</t> <t>cells</t> <t>(WBC).</t> m) Serum albumin (ALB). n) Acute inflammation indicator c-reactive protein (CRP). o) Tumor necrosis factor (TNF-α). p) IL-6. q) IL-10. r) Liver function indicator alanine aminotransferase (ALT). s) Kidney function indicator serum creatinine (Scr). Error bar represents the mean ± SD. Significance was calculated by one-way analysis of variance. ∗∗∗∗ p < 0.0001. N = 4, averaged.
Agriculture Wbc White Blood Cell Count, supplied by Takeda, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/white+blood+cell+(wbc)/5+coupled+g+protein+receptor/pmc12661986-283-150-139
Average 86 stars, based on 1 article reviews
agriculture wbc white blood cell count - by Bioz Stars, 2026-11
86/100 stars
  Buy from Supplier

86
Sysmex Corporation csf white blood cell count wbc
Test of antithrombosis properties of SSCMC in vitro and in vivo . a) Surgical schematic of in vitro blood circulation in rabbits. b) Diagrams of blood cells adhering to the inner lumen of both catheters before and after modification of in vitro blood circulation for 2 h. c) Comparison of blood cells adhering to the surfaces of both catheters before and after modification of the inner lumen of both catheters under SEM. d) ∼ f) Quantification of thrombus weight, lumen occlusion and blood flow rate formed in the lumen of the two catheters, respectively. g) Blood circulation modeling to perform blood correlation analysis. h) Thrombin-antithrombin III enzyme complex (TAT) (an early marker of coagulation activation). i) Tissue-type fibrinogen activator-inhibitor 1 complex (PIC) (risk indicator for venous thromboembolism). j) Thrombomodulin (TM). k) Platelets (PLT). l) <t>White</t> <t>blood</t> <t>cells</t> <t>(WBC).</t> m) Serum albumin (ALB). n) Acute inflammation indicator c-reactive protein (CRP). o) Tumor necrosis factor (TNF-α). p) IL-6. q) IL-10. r) Liver function indicator alanine aminotransferase (ALT). s) Kidney function indicator serum creatinine (Scr). Error bar represents the mean ± SD. Significance was calculated by one-way analysis of variance. ∗∗∗∗ p < 0.0001. N = 4, averaged.
Csf White Blood Cell Count Wbc, supplied by Sysmex Corporation, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/white+blood+cell+(wbc)/cell+channel+precursor+white/pmc12477706-80-0-10
Average 86 stars, based on 1 article reviews
csf white blood cell count wbc - by Bioz Stars, 2026-11
86/100 stars
  Buy from Supplier

Image Search Results


Schematic representation of hiPSC generation using a prototype semi-automated device (A) Leukocyte separation device. This device performs: 1) Fill the flow path with PBS and purge the air. 2) Draw blood from the blood bag into syringe pump #1. 3) Deliver blood from syringe pump #1 and capture white blood cells using cell filter. 4) Rinse away excess red blood cells captured by cell filter with PBS. 5) Flush PBS through syringe pump #2 and collect the white blood cells from cell filter into syringe #3. 6) Deliver the contents of syringe #3 into the spiral flow path to collect leukocytes. (B) Leukocyte culture device. This device performs: 1) Fill the flow path with PBS and purge the air. 2) Draw blood from the blood bag into syringe pump #1. 3) Deliver blood from syringe pump #1 and capture white blood cells using cell filter. 4) Rinse away excess red blood cells captured by cell filter with PBS. 5) Flush PBS through syringe pump #2 and collect the white blood cells from cell filter into syringe #3. 6) Deliver the contents of syringe #3 into the spiral flow path to collect leukocytes. (C) SeV transduction device. This device performs: 1) Recover leukocytes from the previous step using syringe pump #7. 2) Pass the cells from syringe pump #7 through filter #3 and into syringe pump #8 to remove aggregated cells. 3) Transfer the cells from syringe pump #8 to the incubator #2, and mix the leukocytes with SeV vectors. 4) Infect SeV vectors within the incubator #2 to generate hiPSCs. 5) Recover using syringe #11, and transfer these hiPSCs to syringe #13.

Journal: Regenerative Therapy

Article Title: Establishment of polyclonal human induced pluripotent stem cell lines from peripheral blood using a semi-automated processing system

doi: 10.1016/j.reth.2026.101201

Figure Lengend Snippet: Schematic representation of hiPSC generation using a prototype semi-automated device (A) Leukocyte separation device. This device performs: 1) Fill the flow path with PBS and purge the air. 2) Draw blood from the blood bag into syringe pump #1. 3) Deliver blood from syringe pump #1 and capture white blood cells using cell filter. 4) Rinse away excess red blood cells captured by cell filter with PBS. 5) Flush PBS through syringe pump #2 and collect the white blood cells from cell filter into syringe #3. 6) Deliver the contents of syringe #3 into the spiral flow path to collect leukocytes. (B) Leukocyte culture device. This device performs: 1) Fill the flow path with PBS and purge the air. 2) Draw blood from the blood bag into syringe pump #1. 3) Deliver blood from syringe pump #1 and capture white blood cells using cell filter. 4) Rinse away excess red blood cells captured by cell filter with PBS. 5) Flush PBS through syringe pump #2 and collect the white blood cells from cell filter into syringe #3. 6) Deliver the contents of syringe #3 into the spiral flow path to collect leukocytes. (C) SeV transduction device. This device performs: 1) Recover leukocytes from the previous step using syringe pump #7. 2) Pass the cells from syringe pump #7 through filter #3 and into syringe pump #8 to remove aggregated cells. 3) Transfer the cells from syringe pump #8 to the incubator #2, and mix the leukocytes with SeV vectors. 4) Infect SeV vectors within the incubator #2 to generate hiPSCs. 5) Recover using syringe #11, and transfer these hiPSCs to syringe #13.

Article Snippet: The closed-system unit was equipped with a leukocyte separation filter (AP-4951; Cytiva, Marlborough, MA, USA) and a spiral microchannel device (Canon Inc., Tokyo, Japan) for PBMC purification.

Techniques: Automated, Transduction, Incubator

Self-renewal of polyclonal hiPSC lines generated with semi-automated device. (A) Numbers of collected leukocytes after separation in devices. Data are shown in mean with each data value (n=5). (B) Flow cytometry analysis of pluripotent markers, TRA-1-60, during iPSC generation at passages 1 - 4. Data are shown in mean +/- standard errors (n=5). (C) Phase contrast images of hiPSC colonies. Scale bars, 200 μm. (D) Representative flow cytometry analysis of pluripotent markers, SSEA4. (E) Representative flow cytometry analysis of pluripotent markers, TRA-1-60.

Journal: Regenerative Therapy

Article Title: Establishment of polyclonal human induced pluripotent stem cell lines from peripheral blood using a semi-automated processing system

doi: 10.1016/j.reth.2026.101201

Figure Lengend Snippet: Self-renewal of polyclonal hiPSC lines generated with semi-automated device. (A) Numbers of collected leukocytes after separation in devices. Data are shown in mean with each data value (n=5). (B) Flow cytometry analysis of pluripotent markers, TRA-1-60, during iPSC generation at passages 1 - 4. Data are shown in mean +/- standard errors (n=5). (C) Phase contrast images of hiPSC colonies. Scale bars, 200 μm. (D) Representative flow cytometry analysis of pluripotent markers, SSEA4. (E) Representative flow cytometry analysis of pluripotent markers, TRA-1-60.

Article Snippet: The closed-system unit was equipped with a leukocyte separation filter (AP-4951; Cytiva, Marlborough, MA, USA) and a spiral microchannel device (Canon Inc., Tokyo, Japan) for PBMC purification.

Techniques: Generated, Automated, Flow Cytometry, Analysis, Phase Contrast

Test of antithrombosis properties of SSCMC in vitro and in vivo . a) Surgical schematic of in vitro blood circulation in rabbits. b) Diagrams of blood cells adhering to the inner lumen of both catheters before and after modification of in vitro blood circulation for 2 h. c) Comparison of blood cells adhering to the surfaces of both catheters before and after modification of the inner lumen of both catheters under SEM. d) ∼ f) Quantification of thrombus weight, lumen occlusion and blood flow rate formed in the lumen of the two catheters, respectively. g) Blood circulation modeling to perform blood correlation analysis. h) Thrombin-antithrombin III enzyme complex (TAT) (an early marker of coagulation activation). i) Tissue-type fibrinogen activator-inhibitor 1 complex (PIC) (risk indicator for venous thromboembolism). j) Thrombomodulin (TM). k) Platelets (PLT). l) White blood cells (WBC). m) Serum albumin (ALB). n) Acute inflammation indicator c-reactive protein (CRP). o) Tumor necrosis factor (TNF-α). p) IL-6. q) IL-10. r) Liver function indicator alanine aminotransferase (ALT). s) Kidney function indicator serum creatinine (Scr). Error bar represents the mean ± SD. Significance was calculated by one-way analysis of variance. ∗∗∗∗ p < 0.0001. N = 4, averaged.

Journal: Materials Today Bio

Article Title: Robust and ultra-stable nanohesive-based solid-like slippery coating under dynamic blood flow environment for durable prevention of thrombosis and biofouling

doi: 10.1016/j.mtbio.2025.102449

Figure Lengend Snippet: Test of antithrombosis properties of SSCMC in vitro and in vivo . a) Surgical schematic of in vitro blood circulation in rabbits. b) Diagrams of blood cells adhering to the inner lumen of both catheters before and after modification of in vitro blood circulation for 2 h. c) Comparison of blood cells adhering to the surfaces of both catheters before and after modification of the inner lumen of both catheters under SEM. d) ∼ f) Quantification of thrombus weight, lumen occlusion and blood flow rate formed in the lumen of the two catheters, respectively. g) Blood circulation modeling to perform blood correlation analysis. h) Thrombin-antithrombin III enzyme complex (TAT) (an early marker of coagulation activation). i) Tissue-type fibrinogen activator-inhibitor 1 complex (PIC) (risk indicator for venous thromboembolism). j) Thrombomodulin (TM). k) Platelets (PLT). l) White blood cells (WBC). m) Serum albumin (ALB). n) Acute inflammation indicator c-reactive protein (CRP). o) Tumor necrosis factor (TNF-α). p) IL-6. q) IL-10. r) Liver function indicator alanine aminotransferase (ALT). s) Kidney function indicator serum creatinine (Scr). Error bar represents the mean ± SD. Significance was calculated by one-way analysis of variance. ∗∗∗∗ p < 0.0001. N = 4, averaged.

Article Snippet: At predetermined time intervals (after 0, 5, 30, and 60 min of circulation), rabbit blood was collected for biochemical analysis, including thrombin-antithrombin complex (TAT, CUSABIO), fibrinolytic-α2 fibrinolytic inhibitor complex (PIC, mlbio), thrombomodulin (TM, mlbio), platelet (PLT), white blood cell (WBC), serum albumin (ALB, proteintech), C-reactive protein (CRP, proteintech), tumor necrosis factor-α (TNF-α, proteintech), and inflammatory and immunosuppressive factors (IL-6, IL-10, proteintech) to assess physiological parameters such as coagulation, inflammatory response, and organ function.

Techniques: In Vitro, In Vivo, Modification, Comparison, Marker, Coagulation, Activation Assay